Introduction of Flame Retardant Fabric Standards by Flame Retardant Manufacturers

Flame retardant fabrics can be divided into permanent flame retardant fabrics according to their washability. Washability refers to fabrics that can be washed more than 50 times, with flame retardancy, semi-washability, flame retardancy and disposable flame retardancy. Flame-retardant fabrics have different classification standards according to their composition content, including aramid flame-retardant fabrics, ecological flame-retardant fabrics, cotton flame-retardant fabrics, and cvc flame-retardant fabrics. Flame retardant manufacturers said it is different from the functional classification of nylon cotton flame retardant fabric, including anti-static, acid and alkali resistant and oil resistant flame retardant fabric.

Flame retardant fabrics can be divided into permanent flame retardant fabrics according to their washability. Washability refers to fabrics that can be washed more than 50 times, with flame retardancy, semi-washability, flame retardancy and disposable flame retardancy. Flame-retardant fabrics have different classification standards according to their composition content, including aramid flame-retardant fabrics, ecological flame-retardant fabrics, cotton flame-retardant fabrics, and cvc flame-retardant fabrics.flame retardantThe manufacturer stated that it is different from the functional classification of nylon cotton flame retardant fabrics, including anti-static, acid and alkali resistant and oil resistant flame retardant fabrics.
Introduction of Flame Retardant Fabric Standard
Flame retardant fabrics need to have professional testing institutions to carry out special testing on the produced fabrics, and need to carry out very professional performance and fabric testing on flame retardant fabrics in SGS, ITS and other national labor and social security centers, including EN-11611, EN-11612, EN-14116 and other testing institutions. NFPA-2112, ASTM-1506 and GB-8965-2009B. Only qualified products are safe. Full launch.
1. GB8965-98-national flame retardant clothing standards. In 1998, the National Bureau of Standards of China issued the "Industrial Flame Retardant Fabric Clothing Standard" in accordance with the same name standard and similar international standards, which made very detailed regulations on many aspects of flame retardant fabrics, including the overall performance of flame retardant clothing. Flame retardant properties of fabrics and stitches, mechanical properties of garments, structural design and processing of garments, and identification of finished products. and methods of packaging, transportation and inspection.
Two. GA10-91-Performance requirements and test methods for general protective clothing for Chinese firefighters. The Ministry of Public Security of my country recently issued test standards for ordinary protective clothing for firefighters, including the overall performance of flame retardant clothing, the flame retardant properties of stitches and clothing, and the mechanical properties of clothing. Structural design and processing of garments, marking, packaging, transportation and inspection methods of finished products, etc.
3. EN531-EU industrial thermal protective clothing standard. This standard specifies in detail the overall performance, structural design, dimensional stability, flame retardancy, heat resistance and molten metal performance, size signs and markings, user information and identification patterns of flame retardant fabrics.
4. EN479-EU standard for fire protection clothing. This standard specifies the standard of structural fire protection clothing, mainly involving and testing heat and fire protection performance. This standard does not include special tasks such as the removal of spilled chemicals, forest fires, close fire fighting, road accidents requiring rescue, and special fire fighting. These test standards include general requirements and additional requirements.. Important safety requirements, markings, user information and identification patterns

Real-time information

Zhongke Flame Retardant Organization Watches 20 Closing Ceremonies

On the morning of October 22, 2022, members of Zhongke Flame Retardant New Materials Co., Ltd. watched the closing ceremony of the 20th Congress under the leadership of General Manager Wang Ligui.

What are the reasons for the failure of flame retardant after adding aluminum hydroxide flame retardant?

Everyone knows that there are two common flame retardants. Today we are going to talk about only one of them. Aluminum hydroxide flame retardant is an environmentally friendly halogen-free flame retardant, which can be widely used in fabrics, wood, plastics, and rubber., Polyurethane and other industries have ideal flame retardant effect. In the process of industrial application, it is found that flame retardant failure occurs when aluminum hydroxide flame retardant is added. The following are the reasons for the failure of aluminum hydroxide flame retardant, how to prevent it, how to deal with the operation, and restore the original function.

As a flame retardant, magnesium hydroxide also need to improve what aspects?

When it comes to flame retardants, everyone is familiar with them. Although we usually have less contact with them, we can know what they are used for from the name. Have to talk about magnesium hydroxide, we all know that its main presentation state is a granular, at present, the market sales of magnesium hydroxide particle size is larger, part of the commodity particle size up to tens of microns, immediately used as a flame retardant, poor dispersion, the physical properties of raw materials greater harm. In industrial production, physical grinding methods are generally used to reduce the particle size to 1 micron. The surface of magnesium hydroxide has high polarity and is easy to agglomerate. As the compatibility of refractory materials and polymer substrates, it not only reduces its flame retardant grade, but also causes more serious harm to the physical properties of raw materials.